Shyam Instruments and Calibration Services Blog http://www.shyamelectroelectri.com/blog/ Latest Products Mon, 10 May 2021 06:09:00 +0530 en-us http://www.shyamelectroelectri.com Top Advantages of Digital LCR Meter for Industrial Use http://www.shyamelectroelectri.com/blog/top-advantages-of-digital-lcr-meter-for-industrial-use_9679.htm Thu, 19 Nov 2020 16:04:34 +0530 <p style="text-align: justify;">Digital LCR meter is electrical testing tool and it is used to measure the capacity and resistance of electronic components. In Digital LCR Meter readings are accurately shown. Nowadays advanced designs of digital LCR meters are available which showed correct measurement as well as resistance. There are several Wholesale Digital LCR Meter Supplier in Vadodara are offering the meters at affordable prices.<br /><br /></p> <p style="text-align: justify;">There are varieties of LCR meters available in the market, such as Handheld DMM and Benchtop LCR Meters and you can Buy Digital LCR Meter Online. Handheld LCR meters are lightweight, battery-operated, and portable and they are using the DC technique for better performances. Another type of LCR Metres is benchtop which generally has programmable frequencies, better measurement accuracy to 0.01%, and computer control applications. Benchtop LCR meters use AC calibration of inductance, resistance, and dielectric constant measurements with a variety of dielectric cells, and production testing of components and sensors. Here are some of the benefits of Digital LCR Metres:<br /><br /></p> <ul> <li><strong>High Frequency</strong></li> </ul> <p style="text-align: justify; padding-left: 30px;">Electrical components are required to be tested or maintenance required frequently after the application of the equipment. Digital LCR Metres with a huge frequency which is best suitable for industrial uses. Most Digital LCR meters today uses an AC test signal over a frequency range for better performance.<br /><br /></p> <ul> <li><strong>Great Accuracy</strong></li> </ul> <p style="text-align: justify; padding-left: 30px;">These digital LCR Metres have greater accuracy for showing accurate capacity and resistance. These Digital LCR Meters offers accurate measurement and also faster measurement. Due to this reason LCR meters are available with three measurement speeds such as slow, medium, and fast.<br /><br /></p> <ul> <li><strong>No Voltage Problem</strong></li> </ul> <p style="text-align: justify; padding-left: 30px;">Most Digital LCR meters are programmed in such a way that there is no voltage problem and run accurately. Due to its characteristics, it is highly popular for the measurement of resistance and voltage capacitor. Reputed suppliers are leveraging the skills of their qualified team of professionals and providing premium grade components<br /><br /></p> <ul> <li><strong>Testing Frequency</strong></li> </ul> <p style="text-align: justify; padding-left: 30px;">These Digital LCR Metres are available with a large LCD with a single-layer operation menu which provides users with better convenience. These Digital LCR Metres have a high frequency for which the final product is to be utilized. These Digital LCR Meters are consistent in quality that serves the clients enormously.<br /><br /></p> <ul> <li><strong>Accurate Measurement Parameters</strong></li> </ul> <p style="text-align: justify; padding-left: 30px;">These Digital LCR Meters are used for measurements of conductance, and ESR which can be more fully defined as an electrical component. Due to its unique features, Digital LCR Meter Distributor in Gujaratis selling at affordable prices. These Digital LCR Metres are extremely compatible, compact, and lightweight. They are easy to read and also offer clarity in providing accurate information.<br /><br /></p> <ul> <li><strong>User-Friendly to Operate</strong></li> </ul> <p style="text-align: justify; padding-left: 30px;">These Digital LCR Metres are easy to operate and can be easily transferrable from one place to another. Due to its easy operational function, it is highly in demand and can be operated from anywhere. If the tool is user-friendly then training for operation is not required. Due to the availability of Handheld digital LCR Meter suppliers are providing supreme quality materials as per the latest technology embedded within such tools.<br /><br /></p> <p style="text-align: justify;">Thus, above-mentioned benefits of Digital LCR Metres are useful for any industrial work and it is highly required in manufacturing industries where electrical equipment operation is a must. Thus if you are planning for buying LCR Metres for your industry then make you should make proper research about the supplier and then purchase it from an authentic supplier. However, <span style="text-decoration: underline;"><a href="https://www.shyamelectroelectri.com/digital-lcr-meter.htm" target="_self">Wholesale Digital LCR Meter Supplier in Vadodara</a></span> is available and is providing authentic products at affordable prices to the customer. They are providing high-quality products and also maintain their accuracy. Suppliers are providing products which are quality tested, reliable, and also offer hassle free performance to the consumer's needs.</p> Everything That You Need To Know About Digital Clamp Meters http://www.shyamelectroelectri.com/blog/everything-that-you-need-to-know-about-digital-clamp-meters_9916.htm Mon, 11 Jan 2021 13:40:54 +0530 <p style="text-align: justify;">Clamp meters from any digital clamp on power meter supplier are voltage monitors with large braces that can lock around an electric device. The clamp meter is also recognized as Tong Tester too. Originally developed as a single-purpose instrument for measuring AC current, clamp meters also provide inputs to recognize test leads as well as other indicators that enable a vast array of electrical measurements.<br /><br /></p> <p style="text-align: justify;">The clamp meter is often used to figure out the system is healthy or dysfunctional, it can be understood, one of them would be by staring at or calculating the amount of electric current running in the set or electronic devices. You can easily buy digital clamp on power meter online for yourself.<br /><br /></p> <p style="text-align: justify;"><strong>Why Use It?</strong></p> <p style="text-align: justify;">In the event that the current flowing on a system is calculated without the intervention of the network that connects the ampere measurement instrument or via a current transformer, when the connection is disrupted, the electrical supply is interrupted.-<br /><br /></p> <p style="text-align: justify;">The meter won't mess with the current carrier; the torque only surrounds the lead wire.<br /><br /></p> <p style="text-align: justify;">If the device is regular or tasteful, one can be understood to be the electrical current that is flowing into the charge or the electrical system by testing or calculating it; then the magnitude of the electric currents you get is contrasted mostly with rated capacity or operating capacity marked on the electrical devices.<br /><br /></p> <p style="text-align: justify;">Modern clamp meters were originally designed as a testing tool for a specified aim to have more measurement functionality, greater precision, and advanced measuring functions in certain cases. Nowadays, clamps meters from a digital clamp on power meter distributor in Gujarat provide a vast majority of the essential things such as voltage measurement, continuity, and resistance.<br /><br /></p> <p style="text-align: justify;">How To Use It?</p> <p style="text-align: justify;">In accordance with the theory of the current transformer (CT), AC clamp meters operate 1 to measure magnetic flow produced by the flow of electrical current into a conductor. Providing that a flow of voltage through a conductor is the main voltage, some electromagnetic induction via the secondary side (winding) of the transformer attached to the instrument's measurement circuit will produce a voltage equal to the source voltage.<br /><br /></p> <p style="text-align: justify;">For two reasons, in particular, clamp meters have now become common tools:<br /><br /></p> <p style="text-align: justify;"><strong>Safety -</strong></p> <p style="text-align: justify;">Clamp meters enable electricians to avoid the old wire clipping method and introduce a meter test path into the circuit to obtain a line current reading. During calculations, the braces of a clamp meter need not contact a conductor.<br /><br /></p> <p style="text-align: justify;"><strong>Convenience -</strong></p> <p style="text-align: justify;">During a test, a significant improvement in efficiency is not required to shut down the circuit.<br /><br /></p> <p style="text-align: justify;"><strong>Advantages:<br /><br /></strong></p> <p style="text-align: justify;"><strong>No Split Circuits -</strong></p> <p style="text-align: justify;">The electrical power that passes through a system can be measured without having to split circuits. Clamp meter has a multimeter advantage. The flow of current direction can be determined in the live conductor while the wire must be cut and attached to the circuit with the multimeter. A clamp meter is simple to use since it just needs to be clamped to the calibrated conductor. Digital clamp measurements are simple to take into your toolbox and are lightweight. You don't have to operate the system because it's battery operated.<br /><br /></p> <p style="text-align: justify;"><strong>Variety of uses -</strong></p> <p style="text-align: justify;">The clamp meter readings are valid and have a range of functions so that you can use them for different purposes. It saves time since the application needs not to be cut or switched off. This allows the reading method so much more relaxed and confident. There is no major obstacle to the use of a clamp metre by a live electric source. To enable it to function, you only have to substitute the batteries once in a while.<br /><br /></p> <p style="text-align: justify;"><strong>Final Words:</strong></p> <p style="text-align: justify;">You must always select the new models from a <a href="https://www.shyamelectroelectri.com/digital-clamp-on-power-meter.htm">digital clamp on power meter supplier</a> with improved specifications once you buy a clamp meter. Thanks to its flexible nature and robust functionality, it can be used continuously for a long duration.</p> A Complete Guide to Transformer Winding Resistance Testing http://www.shyamelectroelectri.com/blog/a-complete-guide-to-transformer-winding-resistance-testing_10445.htm Wed, 21 Apr 2021 17:29:01 +0530 <p>Measurements of winding resistance are an essential diagnosing tool to evaluate probable transformer damages due to poor design, installation, processing, unfavourable climates, overload or lack of maintenance.</p> <p> </p> <p>The main aim of this testing with a transformer winding resistance meter is to assess whether winding differences or whether connections are open. The measurement of transformer winding resistance ensures that each circuit is efficiently wired and therefore all connections are tight.</p> <p> </p> <p>Transformer winding resistance changes due to shorted turns, loose connections or worsening transformer tap contacts. Whatever their configurations, they are usually phase-to-phase resistance observations and readings are evaluated to one another to determine whether or not they are reasonable. You can easily contact a <a title="Transformer Winding Resistance Meter Supplier" href="https://www.shyamelectroelectri.com/transformer-winding-resistance-meter.htm">transformer winding resistance meter supplier</a>, and get the necessary equipment for yourself.</p> <p> </p> <p><strong>Precautions During Testing</strong>:</p> <p>It is crucial to understand all safety alerts and take appropriate precautions before executing a transformer winding resistance test. Ensure that all devices to be tested have a correct base and that all high-voltage power systems are processed as powered until the appropriate lockout/drainage procedures have been proven otherwise.</p> <p> </p> <p>Where the current still circulates through the transformer mostly during the test, it is essential not to consider removing current or power leads. This leads to the development of an extremely high voltage across the area where voltage is broken and a deadly voltage might also generate.</p> <p> </p> <p><strong>Connecting Test Set</strong>:</p> <p>Together with the main and secondary terminals of the transformer, readings of all windings must be insulated from outer links at each phase. Test device connections must be formulated in the following order:</p> <p> </p> <ul> <li><strong>Ground</strong> - Make sure that only the transformer has been explicitly grounded to the local station and afterwards connect the test soil.</li> <li><strong>Test Leads</strong> - Attach the voltage output to the test set and confirm the strength of all connections with the test pipe detached from the system under test.</li> <li><strong>Connect Transformer</strong> - Every configuration of transformers requires various test connections. Further caution should be given that leads cannot fall off during testing or that leads are connected to or too close to each other. In (between) the current leads and the transformer, the voltage lines should be lined up.</li> <li><strong>Input Power</strong> - Please connect to the test set. Make sure that the available power ground has a low impedance to the ground of the local plant before trying to make this connection.</li> </ul> <p> </p> <p>The following connections could be used for single-phase and simplistic Delta-WYE setups. Please note that every transformer configuration is distinct, and may not cover your particular configuration see the user guide for more information that has come with your test kit.</p> <p> </p> <ul> <li>Single Phase Transformer</li> <li>3-phase Delta Winding</li> <li>3-phase WYE Secondary Winding</li> <li>Dual Winding Test (Single Phase)</li> <li>Dual Winding Test (Three-Phase)</li> </ul> <p> </p> <p>The jumper that connects the two windings must be linked to opposite polarities of the transformer to decrease the fundamental saturation period.</p> <p> </p> <p>When the resistance between the two coils exceeds a factor of 10, measurements which are more accurate by testing each coil individually may be desirable.</p> <p> </p> <p><strong>Winding Resistance Measurements</strong>:</p> <p>The reading must be monitored and recorded when trying to measure winding resistance after the resistance value is reestablished. In the beginning, resistance values would also "drift" due to transformer inductance, which is most common in large delta windings.</p> <p> </p> <p>Drifting only should last for a few seconds on comparatively small transformers, the drift may take as little as a minute for single-phase high-voltage transformers; the drifting time needed for large transformers may take a few minutes or longer. Any current changes will keep changing the value of the resistance.</p> <p> </p> <p><strong>Tap Changer</strong>:</p> <p>Many power transmission and distribution transformers have tap changing devices to increase or reduce the turn ratio contingent on the supply voltage. Due to the mechanical mobility of a change of relation from one situation to another, throughout a winding resistance test, every tap should be verified.</p> <p> </p> <p>During regular maintenance, due to time limitations or other considerations, it will not always be possible to test every tap. In these cases, only the assigned tap position can measure the strength of each winding.</p> <p> </p> <p>The transformer must be unloaded between tap changes for the "Off-load" taps. "On-load" tap changers and voltage regulators may well be controlled also with a test set remaining on it while shifting from tap to tap, this not only saves a lot of time but can also confirm the make before break component of the tap changer.</p> <p> </p> <p><strong>Test Results</strong>:</p> <p>Usually, the analysis of the results of winding strength is compared on the basis of each strength with each adjoining winding with the same tap. If all the measurements are within 1%, the test is considered to have been passed.</p> <p> </p> <p><strong>Final Words</strong>:</p> <p>Comparisons can also be conducted with original test data which are assessed on the production plant using temperature correction data, taking into account that resistance tests on the spot do not repeat the manufacturer's test track, which very often occurred at the time of production in a contained way.</p>